Δωρεάν μεταφορικά για παραγγελίες άνω των 200€ εντός λεκανοπεδίου Αττικής

HUAWEI eKitEngine Router AR730

51155
88980 
Διαθέσιμο 1 έως 3 ημέρες
Διαθεσιμότητα ανά αποθήκη
Αθήνα, Λ. Μεσογείων 20
 
Στην κεντρική αποθήκη
 
Μεταφορικά
Τρόποι Πληρωμής

HUAWEI eKitEngine Router AR730

Technical Specifications

Table 3-22 Technical specifications of the AR730

ItemSpecification
Installation type
  • Rack
  • Work bench
  • Against the wall
Chassis height [U]1 U
Dimensions without packaging (H x W x D) [mm(in.)]
  • Basic dimensions (excluding the parts protruding from the body): 44.4 mm x 442.0 mm x 220.4 mm (1.75 in. x 17.4 in. x 8.68 in.)
  • Maximum dimensions (the depth is the distance from ports on the front panel to the handle on the rear panel): 44.4 mm x 442.0 mm x 225.2 mm (1.75 in. x 17.4 in. x 8.87 in.)
Dimensions with packaging (H x W x D) [mm(in.)]90 mm x 570 mm x 390 mm (3.54 in. x 22.44 in. x 15.35 in.)
Weight with packaging [kg(lb)]4.6 kg (10.12 lb)
Weight without packaging [kg(lb)]3.2 kg (7.04 lb)
CPU1.4 GHz, 4 Cores
Memory4 GB
NAND Flash1 GB
Console portRJ45
RTCSupported
LAN ports8 x GE electrical, 1 x GE combo
WAN ports2 x GE combo, 1 x 10GE optical (SFP+)
Number of service board slots2
MIC slots (default/maximum)0/0
SIC slots (default/maximum)2/2
WSIC slots (default/maximum)0/1
XSIC slots (default/maximum)0/0
Redundant MPUsNot supported
RPS inputNot supported
PoENot supported
IP ratingIP20
MTBF [years]30.05 years
MTTR [hours]2 hours
Availability0.9999924012
Typical power consumption [W]28 W
Maximum power consumption [W]33 W
Power supply modeAC built-in
Number of power modules1
Rated input voltage [V]100 V to 240 V, 50 Hz/60 Hz
Input voltage range [V]90 V to 264 V, 47 Hz to 63 Hz
Maximum input current [A]2 A
Maximum output power [W]70 W
Redundant power supplyNot supported
Type of fansBuilt-in
Number of fan modules1
Heat dissipation modeAir cooling
AirflowLeft-to-right airflow
Noise at normal temperature (acoustic power) [dB(A)]52.3 dB(A)
Long-term operating temperature [°C(°F)]

0°C to 45°C (32°F to 113°F)

NOTE:

When the altitude is 1800–5000 m (5906–16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).

Long-term operating relative humidity [RH]5% RH to 95% RH, non-condensing
Long-term operating altitude [m(ft.)]< 5000 m (16404.2 ft.)
Storage temperature [°C(°F)]-40°C to +70°C (-40°F to +158°F)
Overtemperature alarmSupported


Θύρες Δικτύου
  • 8
Βρες παρόμοια
Επισκευές
Η/Υ - Laptop
Εγκαταστάσεις Λογισμικού
Αναβαθμίσεις
Ανάκτηση Δεδομένων
Δίκτυα Η/Υ
Γρήγορη και ποιοτική παράδοση

Η εταιρεία μας κάνει παράδοση σε όλη την Ελλάδα

Ασφάλεια συναλλαγών

Έχουμε πάρει όλα τα απαραίτητα μέτρα, για να διασφαλίσουμε την ασφάλεια των συναλλαγών.

Τηλεφωνικές παραγγελίες - 2107489060

Δευτέρα-Παρασκευή 9:00-19:00